A randomized clinical trial suggests that simultaneous volume-stable collagen matrix augmentation may help maintain peri-implant soft tissue levels, reduce volumetric shrinkage and improve selected aesthetic outcomes over 12 months.
Immediate implant placement in the anterior aesthetic zone can shorten treatment timelines, but maintaining the soft tissue architecture around the implant remains one of the biggest clinical challenges. Even when implant placement and provisionalisation are carefully planned, soft tissue changes during healing can affect mucosal levels, contour and the final aesthetic result.
A recent randomized clinical trial published in Clinical Oral Implants Research investigated whether simultaneous augmentation using a volume-stable collagen matrix (VCMX) could help preserve soft tissue thickness and improve clinical, aesthetic and patient-reported outcomes around immediate implants.
The findings suggest that adding a volume-stable collagen matrix may offer an advantage in soft tissue stability over the first year following implant placement. Evaluating soft tissue stability over 12 months The randomized clinical trial included 40 patients receiving immediate implants in the anterior aesthetic zone. Participants were assigned to receive immediate implant placement with simultaneous volume-stable collagen matrix augmentation (Test group) or immediate implant placement without the matrix (Control group). Thirty-eight patients completed the study.
Soft tissue thickness (STT) was the primary outcome. Measurements were taken before surgery, immediately after surgery, and at six and 12 months. The investigators also assessed mucosal level, marginal bone level, aesthetic outcomes, patient-reported outcomes and changes in tissue volume.
At all follow-up points, soft tissue thickness was significantly greater in the Test group than in the Control group.
At 12 months, the Test group demonstrated a significant increase in soft tissue thickness measured 3 mm from the gingival margin, with a reported change of 1.85 mm (SE 0.19; p less than 0.0001). At the 6-mm measurement point, the change was 1.29 mm (SE 0.24), although it did not reach statistical significance (p = 0.0917).
In contrast, the Control group showed non-significant decreases in soft tissue thickness at both measurement levels. At 3 mm, the decrease was 0.18 mm (SE 0.18; p = 0.6213), while at 6 mm, it was 0.36 mm (SE 0.10; p = 0.1054).